Quick question:<br><br>When in Labview 7.1 Help, I can no longer load example vi's. I receive a message: "An error occurred ? The NI HelpServer could not be found."<br><br>A search on the NI website finds this issue listed & a solution given for Labview version 7.0. It is suggested to:<br><br>Solution: NI HelpServer is one of two services which open TCP/IP ports to communicate with other NI applications running on your computer, such as the NI Example Finder and the LabVIEW Help. By default, LabVIEW 7.0 will launch this service at startup, however, if it has been disabled you will get this error message. In order to enable the HelpServer, navigate to C:\Program Files\National Instruments\LabVIEW 7.0\resource\system and run the HelpServer.llb. On the front panel of the Set HelpServer Config Settings__NATIONAL INSTRUMENTS.vi you will see a boolean control to enable the server. Turn this switch on and run the VI. The LED indicator in the HelpServer.vi will turn on and you will be able to access the shipping examples from the NI Example Finder.<br><br>One finds a HelpServer.llb / HelpServer Config Settings routine in Labview 7.1 as well, and after setting the LED green, the new error message reads:<br><br>Error 63 occured while trying to open this example using the NI Example VI Finder.<br> <br>Help!